HP StorageWorks ESL9000 Tape Library User Manual
Page 134
Sense Data Values
134
HP StorageWorks ESL9000 Series Tape Library User Guide
0B
8B
10
PASSTHRU INVALID ACTUATOR START POSITION
Pass-through axis position is unknown. Issue a
CALIBRATE ALL
command.
Upgrade firmware to latest revision.
Call your authorized service provider.
0B
8B
60
PTM FULL
The PTM contains a cartridge. Issue a command to retrieve the cartridge
from the PTM and place it in either a bin or a tape drive.
0B
8C 01
LOAD PORT TIMEOUT
The load port door was unlocked, but did not leave its current position
before time-out (30 seconds). This might be due to the door being stuck,
or in the case of a close operation, the operator not moving the door.
0B
8C
09
LOAD PACK DETENT FAILURE
The load pack bin detention spring is unable to hold or release the
cartridge. This is detected during a place if the tape does not stay seated
in the pack or during a pick if the tape does not eject from the pack.
0B
8D
01
DRIVE HANDLE TIMEOUT
Drive handle did not reach commanded position within time limits.
Retry the command.
0B
8F
00
LIBRARY UNIT COMMAND TIMED OUT
Verify that communications to the library still exists by issuing another
command. Check cabling.
Table 26: Sense Data Values (Hexadecimal) (Continued)
Sense
Key
ASC
ASCQ
Message Name/Description