HP StorageWorks ESL9000 Tape Library User Manual
Page 126
Sense Data Values
126
HP StorageWorks ESL9000 Series Tape Library User Guide
04
F3
02
DRIVE COMMUNICATION TIMEOUT
The library is unable to communicate with a drive. Reseat drive module.
04
F3
11
DRIVE HANDLE NOT OK
The tape drive is reporting that the handle cannot open. (This might
indicate that a cartridge is present that has not been unloaded.)
05
1A
00
PARAMETER LIST LENGTH ERROR
Make sure the software supports the library and has the latest patches
and updates.
05
20
00
INVALID COMMAND OPERATION CODE
Make sure the backup software supports the library, and has the latest
patches.
05
21
01
INVALID ELEMENT ADDRESS
Make sure the backup software supports the library, and has the latest
patches.
05
24
00
INVALID FIELD IN COMMAND DATA BLOCK
Make sure the backup software supports the library, and has the latest
patches.
05
25
00
LOGICAL UNIT IS NOT SUPPORTED
Check that the library is configured correctly in the software.
05
26
00
INVALID FIELD IN PARAMETER LIST
Make sure the backup software supports the library, and has the latest
patches.
05
26
02
PARAMETER VALUE INVALID
Make sure the backup software supports the library, and has the latest
patches.
If using the diagnostic utility, check parameters used in last command,
and try again.
Table 26: Sense Data Values (Hexadecimal) (Continued)
Sense
Key
ASC
ASCQ
Message Name/Description