beautypg.com

HP StorageWorks ESL9000 Tape Library User Manual

Page 126

background image

Sense Data Values

126

HP StorageWorks ESL9000 Series Tape Library User Guide

04

F3

02

DRIVE COMMUNICATION TIMEOUT

The library is unable to communicate with a drive. Reseat drive module.

04

F3

11

DRIVE HANDLE NOT OK

The tape drive is reporting that the handle cannot open. (This might

indicate that a cartridge is present that has not been unloaded.)

05

1A

00

PARAMETER LIST LENGTH ERROR

Make sure the software supports the library and has the latest patches

and updates.

05

20

00

INVALID COMMAND OPERATION CODE

Make sure the backup software supports the library, and has the latest

patches.

05

21

01

INVALID ELEMENT ADDRESS

Make sure the backup software supports the library, and has the latest

patches.

05

24

00

INVALID FIELD IN COMMAND DATA BLOCK

Make sure the backup software supports the library, and has the latest

patches.

05

25

00

LOGICAL UNIT IS NOT SUPPORTED

Check that the library is configured correctly in the software.

05

26

00

INVALID FIELD IN PARAMETER LIST

Make sure the backup software supports the library, and has the latest

patches.

05

26

02

PARAMETER VALUE INVALID

Make sure the backup software supports the library, and has the latest

patches.
If using the diagnostic utility, check parameters used in last command,

and try again.

Table 26: Sense Data Values (Hexadecimal) (Continued)

Sense

Key

ASC

ASCQ

Message Name/Description