Sense data values, Table 26: sense data values (hexadecimal), 26 sense data values (hexadecimal) – HP StorageWorks ESL9000 Tape Library User Manual
Page 118

Sense Data Values
118
HP StorageWorks ESL9000 Series Tape Library User Guide
Sense Data Values
lists message information that can be sent from the library to a host
computer
■
Sense key
■
ASC
■
Additional Sense Code Qualifier (ASCQ)
■
Message name, description, and (potential) recovery action
■
Valid interfaces
— SCSI (host computer)
— DIAG (diagnostic port/computer)
— Both = SCSI and DIAG port
The message name and description might contain abbreviations as follows:
■
(A/D) Analog-to-Digital
■
(DEV) Device
■
(DIAG) Diagnostics
■
(LU) Logical Unit
■
(NVRAM) Nonvolatile RAM
■
(REQ’D) Required
Table 26: Sense Data Values (Hexadecimal)
Sense
Key
ASC
ASCQ
Message Name/Description
-none- 30
03
CLEANING CARTRIDGE INSTALLED
Indicates that the element contains a cleaning cartridge that is not
used-up. This is returned with the element status data, which has no sense
key.
-none- 80
01
DRIVE REQUIRES CLEANING
Tape drive indicates that drive needs cleaning. Clean the tape drive. This
is returned with element status data, which has no sense key.
00
00
00
NO ADDITIONAL SENSE INFORMATION
No recovery necessary.
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- XP Array Manager Software (101 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant High Availability Storage Server (72 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)