HP StorageWorks ESL9000 Tape Library User Manual
Page 122
Sense Data Values
122
HP StorageWorks ESL9000 Series Tape Library User Guide
04
83
22
EXTENSION ENCODER FAILURE
The value of the extension encoder did not change during the self-test.
Visually inspect extension axis and belt, look for debris, excessive wear of
damage.
04
83
40
EXTENSION FORCE NOT REACHED
During calibration or pushing in a drive, the extension never reached its
intended force.
If error is occurring during a place to a drive, ensure drive is securely
installed.
04
83
41
EXTENSION FORCE OBJECT MISSING
During calibration or pushing in a drive, the extension never made
contact with any object.
Verify the electronic model number and configuration matches physical
configuration of library. This error will be returned if a bin is not installed,
which is expected by the model number configured.
If error is occurring during a drive calibration, ensure drive is securely
installed.
04
83
50
EXTENSION SENSOR FAIL
The Cartridge In Gripper (CIG) sensor was occluded unexpectedly during
calibration, inventory or pick/place.
Retry the command.
04
84
00
VERTICAL INTERNAL FAILURE
Vertical axis code internal failure.
Upgrade firmware to latest revision.
Call your authorized service provider.
04
84
03
VERTICAL MECHANICAL POSITION ERROR
Vertical axis did not reach desired position.
Retry command.
Determine if something is obstructing the vertical axis motion. Determine
the cause of the obstruction by repeating the command that failed. If a
tape is colliding with a bin or drive, then a
CALIBRATE ALL
command
may clear the condition.
Table 26: Sense Data Values (Hexadecimal) (Continued)
Sense
Key
ASC
ASCQ
Message Name/Description