HP StorageWorks ESL9000 Tape Library User Manual
Page 121
Sense Data Values
121
HP StorageWorks ESL9000 Series Tape Library User Guide
04
82
20
ROTARY TEST FAILURE
Call your authorized service provider.
04
82
23
ROTARY POSITION OVERFLOW
The position step counter overflowed. Issue a
CALIBRATE ALL
command.
04
83
00
EXTENSION INTERNAL FAILURE
Upgrade firmware to latest revision.
Extension axis code internal failure.
Call your authorized service provider.
04
83
01
EXTENSION TIMEOUT
Retry the command.
If failure recurs, then run extension self-test.
04
83
02
EXTENSION CURRENT FEEDBACK FAILURE
Determine if something is obstructing the extension axis motion.
Determine the cause of the obstruction by repeating the command that
failed. If a tape is colliding with a bin or drive, then issue a
CALIBRATE
ALL
command.
Visually inspect extension axis and belt, look for debris, excessive wear of
damage.
04
83
03
EXTENSION MECHANICAL POSITION ERROR
Determine if something is obstructing the extension axis motion.
Determine the cause of the obstruction by repeating the command that
failed. If a tape is colliding with a bin or drive, then recalibrating the
system may clear the condition.
Visually inspect extension axis and belt, look for debris, excessive wear of
damage.
04
83
08
EXTENSION HOME NOT FOUND
Check extension home sensor and flag.
Visually inspect extension axis and belt, look for debris, excessive wear of
damage.
04
83
20
EXTENSION TEST FAILURE
The value of the extension encoder did not change during the self-test.
Visually inspect extension axis and belt, look for debris, excessive wear of
damage.
Table 26: Sense Data Values (Hexadecimal) (Continued)
Sense
Key
ASC
ASCQ
Message Name/Description