Sense Data Values

120

HP StorageWorks ESL9000 Series Tape Library User Guide

04

80

0F

LOW POWER ERROR

Check power connections, and check for failed power supplies.

04

80

11

MOTOR POWER FAILURE

Indicates motor power turned off for a reason not otherwise reported.

Toggle of the Stop button should clear.
If the motor power failure occurs after the action of closing the door, or

when the door is not latched, then upgrade firmware to latest revision.
Check door switches.
Check for one or more faulty Power Supply Modules.

04

80

23

BARCODE DECODER COMMUNICATION FAILURE

Unable to initialize decoder.Check cable connections around Y-axis

interconnect.

04

81

00

GRIPPER AXIS INTERNAL FAIL

Gripper axis code internal failure.
Contact your HP service representative.

04

81

54

GRIPPER TPU REGISTER FAILURE

Replace robotic controller board.

04

81

55

GRIPPER TPU RAM FAILURE

Replace robotic controller board.

04

82

00

ROTARY AXIS INERNAL FAIL

Upgrade firmware to latest revision.
Call your authorized service provider.

04

82

01

ROTARY TIMEOUT

The rotary axis did not reach the desired position within the time limit.

Retry the command. If the failure recurs, contact your authorized service

provider.

04

82

08

ROTARY HOME NOT FOUND

The home flag was not found. Run a

CALIBRATE ALL

command.

04

82

10

ROTARY INVALID START

The rotary axis has not been homed yet. Issue a

CALIBRATE ALL

command.
Call your authorized service provider.
Upgrade firmware to latest revision.

Table 26: Sense Data Values (Hexadecimal) (Continued)

Sense

Key

ASC

ASCQ

Message Name/Description