beautypg.com

HP StorageWorks ESL9000 Tape Library User Manual

Page 133

background image

Sense Data Values

133

HP StorageWorks ESL9000 Series Tape Library User Guide

0B

82

05

ROTARY BACK FAILURE

The rotary move to the back position failed. Retry the command. If the

failure recurs, issue a

SELF-TEST

command.

Replace the robotics controller.

0B

83

01

EXTENSION TIMEOUT

Extension axis did not reach desired position.
Retry command.

0B

83

10

EXTENSION INVALID ACTUATOR START POSITION

Extension axis position is unknown. Issue a

CALIBRATE ALL

command.
Upgrade firmware to latest revision.
Call your authorized service provider.

0B

84

01

VERTICAL TIMEOUT

Vertical axis did not reach desired position within the time limits.
Retry command.

0B

84

10

VERTICAL INVALID ACTUATOR START POSITION

Position of vertical axis is unknown. Issue a

CALIBRATE ALL

command.
Upgrade firmware to latest revision.
Call your authorized service provider.

0B

85

01

HORIZONTAL TIMEOUT

Horizontal axis did not reach desired position within the time limits.
Retry command.

0B

85

10

HORIZONTAL INVALID ACTUATOR START POSITION

Position of horizontal axis is unknown. Issue a

CALIBRATE ALL

command.
Upgrade firmware to latest revision.
Call your authorized service provider.

0B

8B

01

PASSTHRU TIMEOUT

Pass-through axis did not reach desired position. Retry command.

Table 26: Sense Data Values (Hexadecimal) (Continued)

Sense

Key

ASC

ASCQ

Message Name/Description