HP StorageWorks ESL9000 Tape Library User Manual
Page 133
Sense Data Values
133
HP StorageWorks ESL9000 Series Tape Library User Guide
0B
82
05
ROTARY BACK FAILURE
The rotary move to the back position failed. Retry the command. If the
failure recurs, issue a
SELF-TEST
command.
Replace the robotics controller.
0B
83
01
EXTENSION TIMEOUT
Extension axis did not reach desired position.
Retry command.
0B
83
10
EXTENSION INVALID ACTUATOR START POSITION
Extension axis position is unknown. Issue a
CALIBRATE ALL
command.
Upgrade firmware to latest revision.
Call your authorized service provider.
0B
84
01
VERTICAL TIMEOUT
Vertical axis did not reach desired position within the time limits.
Retry command.
0B
84
10
VERTICAL INVALID ACTUATOR START POSITION
Position of vertical axis is unknown. Issue a
CALIBRATE ALL
command.
Upgrade firmware to latest revision.
Call your authorized service provider.
0B
85
01
HORIZONTAL TIMEOUT
Horizontal axis did not reach desired position within the time limits.
Retry command.
0B
85
10
HORIZONTAL INVALID ACTUATOR START POSITION
Position of horizontal axis is unknown. Issue a
CALIBRATE ALL
command.
Upgrade firmware to latest revision.
Call your authorized service provider.
0B
8B
01
PASSTHRU TIMEOUT
Pass-through axis did not reach desired position. Retry command.
Table 26: Sense Data Values (Hexadecimal) (Continued)
Sense
Key
ASC
ASCQ
Message Name/Description