migrate unit
Description
Migrates an existing LUN from one RAID level to another. If you attempt to
move to an unsupported RAID configuration for a LUN, an error message
is displayed.
NOTE:
Before changing the RAID level or stripe size of a LUN, verify there is
available, unused space on the array. Migrating from one RAID level
to another may require additional space for parity and organizational
purposes.
Syntax
migrate unit <unit> raid_level=<raid level>
[stripe_size=<size>]
Operands
<unit>
The number (0-31) of the LUN to modify.
raid_level=<raid level>
The RAID fault-tolerance level to use. RAID levels include:
• 0 = RAID 0 (no fault tolerance)
• 1 = RAID 1 (mirroring)
• 5 = RAID 5 (distributed parity)
• 6 = RAID 6 (Advanced Data Guarding)
NOTE:
If more than one pair of drives are included in a RAID 1 array, the
data is striped across the first half of the drives in the array and then
each drive is mirrored to a drive in the remaining half of the drives for
fault tolerance. This method is referred to as RAID 1+0.
stripe_size=<size>
[Optional] The stripe size to assign (in KB). Options include:
• RAID 0 uses stripe sizes 8, 16, 32, 64, 128, and 256 (Default: 128 KB)
• RAID 1 uses stripe sizes 8, 16, 32, 64, 128, and 256 (Default: 128 KB)
• RAID 5 uses stripe sizes 8, 16, 32, and 64 (Default: 16 KB)
• RAID ADG uses stripe sizes 8, 16, 32, and 64 (Default: 16 KB)
Example
To migrate unit 0 to RAID 5 with a stripe size of 32 KB:
CLI> migrate unit 0 raid_level=5 stripe_size=32
The RAID level of Unit 0 will now be 5.
Unit 0 is being migrated.
Use “show unit 0” to monitor progress.
See also
•
•
•
1510i Modular Smart Array Command Line Interface user guide
71