beautypg.com

Enable slp discovery of the iscsi target, Configure static management settings, Configuring static management settings – HP StorageWorks 1510i Modular Smart Array User Manual

Page 23

background image

iSNS enabled

To manually add iSNS servers

a.

Use the

set isns

command to change the iSNS server discovery mode:

CLI> set isns server_discovery=manual

iSNS parameters set.

b.

Use the

add isns_server

command to add the IP address of the iSNS server:

CLI> add isns_server 20.20.20.26

The iSNS server was added successfully.

Alias:

isns1

c.

Use the

set discovery

command to enable iSNS discovery on the iSCSI target.

CLI> set discovery target1 isns=enable

iSNS enabled

Enable SLP discovery of the iSCSI target

NOTE:

Steps in this section assume that you already have a basic iSCSI setup configured.

Use the

set discovery

command to enable SLP discovery on the iSCSI target:

CLI> set discovery target1 slp=enable

SLP enabled

Configure static management settings

To access the MSA1510i management functionality over a network that does not use DHCP, and on which

your management host cannot access the default zeroconf* IP address, you must set up a static IP address.

1.

Configure management to use a static IP address using the

set management

command:

CLI> set management dhcp=disable ip=192.168.1.10/255.255.255.0

gateway=192.168.1.1

2.

[Optional] If you have not done so already, configure a login and password for accessing

management functionality using the

set management_login

command:

CLI> set management_login <user_ID> <password>
where <user_ID> and <password> are your own unique settings.

3.

[Optional] Switch management functionality to a different physical port using the

set management

command:
CLI> set management port=MA1

1510i Modular Smart Array Command Line Interface user guide