12.
Restart the MSA and its attached storage enclosures storage system by doing the following (newly
downloaded firmware cannot be accessed until the MSA is restarted):
a. Press and hold down the MSA Power On/Standby button for approximately five seconds to
place the MSA in Standby mode.
b. Power off all storage enclosures attached to the MSA.
c. Wait approximately two minutes to ensure that the hard disk drives in the enclosures stop
rotating.
d. Restart all storage enclosures attached to the MSA.
e. Wait approximately four minutes to allow the enclosures to complete their startup routines.
f. Press and release the MSA Power On/Standby button to restart the MSA.
g. Wait (up to eight minutes) for the STARTUP COMPLETE message to display on the MSA
controller LCD panel.
13.
View the messages displayed on the array controller LCD panel during startup to confirm that the
firmware was installed successfully and that the array controller restarts successfully.
NOTE:
In dual-controller configurations, firmware on the two controllers is compared each time
the MSA chassis is restarted. If the versions are mismatched, the system prompts to clone
the firmware on the controller with the latest version over to the controller with the earlier
version firmware. (For the system to operate in a dual-controller mode, firmware on the
controllers must match.)
The following message is displayed on the LCD panel of the controller with the earlier
firmware:
07 CLONE FIRMWARE ? ‘<‘ = NO, ‘>’ = YES
Press the > button on the LCD panel to clone the firmware. During the cloning process,
informational messages are displayed on the controller LCD panels. When the cloning
process is complete, the just-updated controller automatically restarts.