12.

Restart the MSA and its attached storage enclosures storage system by doing the following (newly

downloaded firmware cannot be accessed until the MSA is restarted):
a. Press and hold down the MSA Power On/Standby button for approximately five seconds to

place the MSA in Standby mode.

b. Power off all storage enclosures attached to the MSA.
c. Wait approximately two minutes to ensure that the hard disk drives in the enclosures stop

rotating.

d. Restart all storage enclosures attached to the MSA.
e. Wait approximately four minutes to allow the enclosures to complete their startup routines.
f. Press and release the MSA Power On/Standby button to restart the MSA.
g. Wait (up to eight minutes) for the STARTUP COMPLETE message to display on the MSA

controller LCD panel.

13.

View the messages displayed on the array controller LCD panel during startup to confirm that the

firmware was installed successfully and that the array controller restarts successfully.

NOTE:

In dual-controller configurations, firmware on the two controllers is compared each time

the MSA chassis is restarted. If the versions are mismatched, the system prompts to clone

the firmware on the controller with the latest version over to the controller with the earlier

version firmware. (For the system to operate in a dual-controller mode, firmware on the

controllers must match.)
The following message is displayed on the LCD panel of the controller with the earlier

firmware:
07 CLONE FIRMWARE ? ‘<‘ = NO, ‘>’ = YES
Press the > button on the LCD panel to clone the firmware. During the cloning process,

informational messages are displayed on the controller LCD panels. When the cloning

process is complete, the just-updated controller automatically restarts.

newpage pi

64

Command reference