show auto_path_change

Description

Shows whether implicit (automatic) path changing enabled and lists the

criteria that must be met for an automatic LUN ownership change.

Syntax

show auto_path_change

Operands

None

Example

CLI> show auto_path_change

Implicit (automatic load-based) LUN ownership changes are currently ENABLED.

Implicit LUN ownership change preferences are as follows:

Minimum % of proxied requests to trigger implicit path change..:

75%

Minimum number of requests to LUN before path change enabled...:

128

Minimum time to wait before changing ownership after power-up..:

30 minutes

Minimum time between ownership changes for LUN.................:

30 minutes

See also

set auto_path_change

show preferred_path