beautypg.com

Show this_controller|other_controller, Show this_controller/other_controller – HP StorageWorks 1510i Modular Smart Array User Manual

Page 134

background image

show this_controller|other_controller

Description

Displays configuration information for the specified controller, such as:
• Serial number
• Hardware/software revision
• Controller identifier
• SCSI version
• Redundancy mode
• SCSI address
• Read/write cache ratio
• Cache version, cache status, and cache battery status

Syntax

show this_controller|other_controller

Operands

this_controller

Show the configuration of the controller that the CLI is connected to.

other_controller

Show the configuration for the other controller.

Example

CLI> show this_controller

Controller:

MSA1510i(c) Hewlett-Packard P855BX6X3QY00K Version 0.56 Build 2

Hardware 7

Component Enclosure.

Controller Identifier:

SCSI_VERSION = SCSI-3

Supported Redundancy Mode: Active/Active

Current Redundancy Mode: Not Redundant (No Failure)

Device Port SCSI address 6

Terminal speed for the CLI is set to 19200.

Cache:

77 megabyte read cache

179 megabyte write cache

Version 2

Cache is GOOD, and Cache is enabled.

No unflushed data in cache.

Battery:

Module #1 is fully charged and turned off.

Controller Up Time:

0 Days 23 Hours 49 Minutes 46 Seconds

Health:

Surface Scan:

Complete.

Rebuild Status: Complete.

Expansion:

Complete.

See also

show service

newpage pi

134