show this_controller|other_controller
Description
Displays configuration information for the specified controller, such as:
• Serial number
• Hardware/software revision
• Controller identifier
• SCSI version
• Redundancy mode
• SCSI address
• Read/write cache ratio
• Cache version, cache status, and cache battery status
Syntax
show this_controller|other_controller
Operands
this_controller
Show the configuration of the controller that the CLI is connected to.
other_controller
Show the configuration for the other controller.
Example
CLI> show this_controller
Controller:
MSA1510i(c) Hewlett-Packard P855BX6X3QY00K Version 0.56 Build 2
Hardware 7
Component Enclosure.
Controller Identifier:
SCSI_VERSION = SCSI-3
Supported Redundancy Mode: Active/Active
Current Redundancy Mode: Not Redundant (No Failure)
Device Port SCSI address 6
Terminal speed for the CLI is set to 19200.
Cache:
77 megabyte read cache
179 megabyte write cache
Version 2
Cache is GOOD, and Cache is enabled.
No unflushed data in cache.
Battery:
Module #1 is fully charged and turned off.
Controller Up Time:
0 Days 23 Hours 49 Minutes 46 Seconds
Health:
Surface Scan:
Complete.
Rebuild Status: Complete.
Expansion:
Complete.
See also
•
newpage pi
134