Show unit – HP StorageWorks 1510i Modular Smart Array User Manual
Page 135
show unit
Description
Displays information about the specified LUN, or all defined LUNs. The
show unit and show units commands are identical in functionality.
The following information can be displayed:
• Unit identifier (user-defined name)
• Volume status, including OK, Failed, and Rebuilding
• List of the disks included in the LUN
• Spare disks included in the LUN
• RAID level
• Stripe size
• Logical volume capacity
Syntax
show unit [<unit>]
-or-
show units [<unit>]
Operands
<unit>
[Optional] The LUN unit number to display. If no value is entered, then
information for all units is displayed.
Example 1
To show information about LUN 1:
CLI> show unit 1
Unit Identifier
:
Device Identifier :
600508B3-00900E40-70C85A91-01DA0068
Cache Status
: Enabled
Max Boot Partition: Enabled
Volume Status
: VOLUME OK
11 Data Disk(s) used by lun 1:
Disk101: Box 1, Bay 01, (B:T:L 0:00:00)
Disk102: Box 1, Bay 02, (B:T:L 0:01:00)
Disk103: Box 1, Bay 03, (B:T:L 0:02:00)
Disk104: Box 1, Bay 04, (B:T:L 0:03:00)
Disk105: Box 1, Bay 05, (B:T:L 0:04:00)
Disk106: Box 1, Bay 06, (B:T:L 0:05:00)
Disk107: Box 1, Bay 07, (B:T:L 0:08:00)
Disk108: Box 1, Bay 08, (B:T:L 0:09:00)
Disk109: Box 1, Bay 09, (B:T:L 0:10:00)
Disk110: Box 1, Bay 10, (B:T:L 0:11:00)
Disk111: Box 1, Bay 11, (B:T:L 0:12:00)
Spare Disk(s) used by lun 1:
No spare drive is designated.
Logical Volume Raid Level: NO FAULT TOLERANCE (Raid 0)
stripe_size=128kB
Logical Volume Capacity : 20,473MB
Example 2
To show information about all LUN units:
CLI> show unit
-or-
CLI> show units
1510i Modular Smart Array Command Line Interface user guide
135