Command line 64
Item
Description
(required)
server port. The format of the ConnectionId is
Network (required) The name of a valid Ethernet network on which the mapping exists
Properties
VLanID (optional)
The new VLAN ID to be used for the mapping server port to network. Valid values
include 1 to 4094.
Untagged (optional) Enables or disables the network to handle untagged packets. Only one network in
an Ethernet network connection is allowed to handle untagged packets. The default
value is "false". If a shared uplink set is being used, the untagged network is the
same as the native network if present, but any network can also be configured to
handle untagged packets.
When changing a network untagged option from true to false, the user is required
to provide a VLanID if the global option SharedServerVLanId is set to "false".
Examples
->set server-port-map MyProfile:1 Network1 VLanId=100
Modifies the VLAN ID of an existing server port network mapping
->set server-port-map MyProfile:1 Network1 Untagged=true
Modifies the existing server port network mapping to handle untagged packets
Item
Description
show server-port-map Display a server port network mapping. This command cannot be used if the
domain setting, VLanTagControl, is set to "Tunnel".
Syntax
show server-port-map [
Parameter
ConnectionID
(optional)
The reference ID of an existing enet-connection associated with a profile and a
server port. The format of the ConnectionId is
Examples
->show server-port-map
Lists all the server port mappings
->show server-port-map MyProfile:1
Displays the server port mapping for a profile
->show server-port-map *
Displays detailed output of all the server port mappings
snmp
View and modify the SNMP configuration for VC-Enet and VC-FC modules, and add, modify, and remove
SNMP trap configurations related to trap destinations.
Supported actions: set, show, help
Item
Description
set snmp
Modify the VC SNMP configuration.
Syntax
set snmp
[SystemContact=
[SmisEnabled=
Parameter
Type (required)
Indicates which SNMP configuration to modify. Valid values include "Enet" and
"FC".
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem