Fc-connection – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 30

Command line 30
Item
Description
"4Gb", and “8Gb”. The default port speed is “Auto”.
Speed restrictions:
•
For the HP 4Gb VC-FC Module and HP Virtual Connect 4Gb FC Module, valid
speed values include "Auto", "2Gb", and "4Gb".
•
For the HP VC 8Gb 24-Port FC Module, HP VC 8Gb 20-Port FC Module, and HP
VC FlexFabric 10Gb/24-Port Module valid speed values include
"Auto","2Gb","4Gb", and "8Gb".
LinkDist
(optional)
Specifies the login re-distribution scheme for load balancing. Valid values include
"Auto" and "Manual". The default login re-distribution is "Manual".
The HP 4Gb VC-FC Module, HP Virtual Connect 4Gb FC Module, HP VC 8Gb 20-Port
FC Module, and HP VC 8Gb 24-Port FC Module support only Manual login
re-distribution. The HP VC FlexFabric 10Gb/24-Port Module supports both Auto and
Manual login re-distribution schemes.
Ports (optional) A list of one or more logical FC ports to be added to the fabric. Each port is specified
in the format "
modified in the fabric (affects all modules within a bay group).
For HP VC FlexFabric 10Gb/24-Port Modules, port numbers 1, 2, 3, and 4 correspond
to ports X1, X2, X3, and X4, respectively.
Examples
->set fabric MyFabric1 Name=MyNewName1
Changes the name of an existing fabric
->set fabric MyFabric2 Speed=2Gb LinkDist=Auto
Modifies the port speed and login re-distribution
->set fabric MyFabric3 Ports=1,2,3,4
Modifies the fabric ports contained in the fabric
->set fabric MyFabric5 -loadBalance
Performs load balancing on a fabric with manual login re-distribution
Item
Description
show fabric
Display all FC SAN fabric information.
Syntax
show fabric [
Parameter
Name (optional)
Name of an existing FC SAN fabric. “*” displays a detailed output of all the fabrics in
the VC domain. If not specified, a summary output of all fabrics appears.
Examples
->show fabric
Displays a summary listing of all FC SAN fabrics
->show fabric *
Displays detailed information for all FC SAN fabrics
->show fabric SAN_5
Displays detailed information for a specific FC SAN fabric
fc-connection
Manage Fibre Channel SAN connections.
Supported actions: add, help, remove, set, show
Item
Description
add fc-connection
Add a new FC SAN connection to an existing server profile.
For more information, see "General requirements for adding FC or FCoE
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem