Profile – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 56

Command line 56
profile
Manage server profiles.
Supported actions: add, assign, help, remove, set, show, unassign
Item
Description
add profile
Create a new server profile. After the profile has been created, the profile can then
be configured using the "set" subcommand, and the additional network, fabric,
and FCoE connections can also be added. The server profile can also be assigned
to a device bay using the "assign" subcommand.
Syntax
add profile
[-NoDefaultFcConn] [-NoDefaultFcoeConn]
[SNType=
[SerialNumber=
Parameter
ProfileName
The unique name of the new server profile to create
Options
NoDefaultEnetConn
Do not add default Ethernet Network connections when creating the server profile.
NoDefaultFcConn
Do not add default FC SAN connections when creating the server profile.
NoDefaultFcoeConn
Do not add default FCoE SAN connections when creating the server profile.
Properties
SNType (Optional)
The source of the serial number assignment to be used during the profile creation.
If not specified, the serial number is assigned according to the Virtual connect
default domain settings. Valid values include "Factory-Default" and "User-Defined".
SerialNumber
(required if the
SNType is
User-Defined)
A custom user-defined serial number associated with the server profile. When the
profile is assigned to a device bay that contains a server, the server inherits the
virtual serial number. The user-defined serial number must start with the pattern
VCX01.
UUID (Optional)
A unique 128-bit identifier for the virtual server ID. The format is
xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx, where x is any alpha-numeric character. If
no UUID is specified, then one is auto-generated. The UUID can be specified only if
the SNType is User-Defined.
Examples
->add profile MyNewProfile
Creates a new profile and adds it to the domain, using default connections and
Virtual Connect default serial numbers
->add profile MyNewProfile2 -NoDefaultEnetConn
Creates a new profile without adding default Ethernet connections
->add profile MyNewProfile2 -NoDefaultFcConn
Creates a new profile without adding default FC connections
->add profile MyNewProfile2 -NoDefaultFcoeConn
Creates a new profile without adding default FCoE connections
->add profile MyNewProfile2 -NoDefaultEnetConn
-NoDefaultFcConn
Creates a new profile without adding default Ethernet and FC connections
->add profile MyNewProfile2 -NoDefaultEnetConn
-NoDefaultFcConn -NoDefaultFcoeConn
Creates a new profile without adding default Ethernet, FC, and FCoE connections
->add profile MyNewProfile SNType=User-Defined
SerialNumber=VCX0113121
Creates a new profile and specifies a custom virtual serial number
->add profile MyNewProfile SNType=Factory-Default
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem