HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 27

Command line 27
Item
Description
MacType, WwnType, and ServerIdType.
Syntax
remove external-manager [-quiet] [UserName=
[MacType= address>] [MacEnd= [WwnType= address>] [WwnEnd= [ServerIdType= [ServerIdStart= address>] Option quiet This option suppresses user confirmation prompts and is useful when scripting Properties UserName (optional) A valid external manager user name. The user name can be identified using the show external-manager command. MacType (optional) The type of MAC address source to use for assignment. Valid values include "Factory-Default" and "User-Defined". MacStart (required if the MacType is User-Defined) The starting MAC address in a custom user-defined range. This property is only valid if the MacType is set to "User-Defined". MacEnd (required if the MacType is User-Defined) The ending MAC address in a custom user-defined range. This property is only valid if the MacType is set to "User-Defined". WwnType (optional) The type of WWN address source to use for assignment. Valid values include "Factory-Default" and "User-Defined". WwnStart (required if the WwnType is User-Defined) The starting WWN address in a custom user-defined range WwnEnd (required if the WwnType is User-Defined) The ending WWN address in a custom user-defined range ServerIdType (optional) The type of the virtual serial number source. When server profiles are created, the ServerIdStart (required if Type is User-Defined) The starting serial number in a user-defined range. This property is only valid for ServerIdEnd (required if Type is User-Defined) The ending serial number in a user-defined range. This property is only valid for Examples ->remove external-manager UserName=A17005068 Removes only the external management control of the VC Manager ->remove external-manager macType=Factory-Default wwnType=Factory-Default serverIdType=Factory-Default Releases only the profile control ->remove external-manager username=A1010345 macType=Factory-Default wwnType=Factory-Default serverIdType=Factory-Default Removes the external manager and releases the profile control ->remove external-manager username=A19216811 mactype=User-Defined MacStart=00-17-A4-77-00-00 MacEnd=00-17-A4-77-03-FF wwnType=User-Defined WwnStart=50:06:0B:00:00:C2:62:00 WwnEnd=50:06:0B:00:00:C2:65:FF serverIdType=User-Defined
operations.
virtual serial numbers and UUID values are allocated from the specified pool
source. Valid values include "Factory-Default" and "User-Defined".
user-defined serial number types.
user-defined serial number types.
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem