HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 67

Command line 67
Item
Description
->remove snmp-trap *
Removes all configured SNMP trap destinations
Item
Description
set snmp-trap
Modifies an existing SNMP trap destination
Syntax
set snmp-trap name>][Address= address>][Community= | SNMPv2>][Severity= All|None>][DomainCategory= All|None>][EnetCategory= All|None>][FcCategory= Parameter TrapName (required) The name of the trap to be modified Name New name of the trap Address (required) IPv4 address or DNS name for the trap destination maximum string length is 39. For VC-FC modules, the maximum string length is 24. If not specified, the default community name is "public". Format Format of the new trap. Valid values are "SNMP1v" and "SNMPv2". The default is Severity Trap severities to send to the destination. Valid values are "Normal", "Unknown", Multiple severities can be provided, separated by commas. The default severity is DomainCategories The Virtual Connect Domain trap categories to send to the destination. Valid values are "Legacy", "DomainStatus", "NetworkStatus", "FabricStatus", "ProfileStatus", EnetCategories The Virtual Connect Ethernet trap categories to send to the destination. Valid values Multiple categories can be specified, separated by commas. FcCategories The Virtual Connect Fibre Channel trap categories to send to the destination. Valid Multiple categories can be specified, separated by commas. Examples ->set snmp-trap MyTrap1 Community=public Sets the trap community ->set snmp-trap MyTrap1 Severity=All FcCategories=None EnetCategories=None Sets all trap severities, and also sets the Fibre Channel and Ethernet categories to Item Description ->show snmp-trap Displays the SNMP traps that have been configured Syntax show snmp-trap [Name| *] Parameter Name (optional) The name of the trap configuration to be displayed. If no trap name is specified, or
Properties
Community (optional) The SNMP community name string for the specified trap. For VC-Enet modules, the
"SNMPv1".
"Info", "Warning", "Minor", "Major", "Critical", "All", and "None".
"None".
"ServerStatus", "EnetStatus", FcStatus", "All", and "None".
Multiple categories can be specified, separated by commas.
are "PortStatus", "PortThreshold", "Other", "All", and "None".
values are "PortStatus", "Other", "All", and "None".
none
"*" is entered, then all configured traps are displayed.
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem