Page 81

Command line 81
assign profile MyProfile enc0:1
•
Management element help—provides a listing of objects that are supported with a specific
subcommand and a brief description of the management element and what it represents in the
management model:
->help devicebay
General Enclosure Device Bay settings and information
Supported Subcommands:
help
show
-----------------------------------------------------------------------
->show devicebay -help
Description:
This command displays all device bays in the domain
Syntax:
show devicebay [
Parameters:
DeviceBayName : The reference name of a device bay in the domain.
The format of the device bay name is
Examples:
- Display a summary listing of all device bays:
->show devicebay
- Show detailed information for all device bays:
->show device bay *
- Show detailed information for a specific device bay 2 of
a specific enclosure:
->show devicebay enc0:2
Output format
The CLI provides two different output formats:
•
Interactive user output format
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem