HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 66

Command line 66
Item
Description
category|All|None>][FcCategories= category|All|None>] Parameter Name (required) A unique name for the new trap being added Properties Address (required) IPv4 address or DNS name for the trap destination "public" if not specified. For VC-Enet modules, the maximum string length is 39. For Format Format of the new trap. Valid values are "SNMPv1" and "SNMPv2". The default is "SNMPv1" if not specified. Severities Trap severities to send to the destination. Valid values are "Normal", "Unknown", "Info", "Warning", "Minor", "Major", "Critical", "All", and "None". DomainCategories The Virtual Connect Domain trap categories to send to the destination. Valid values Multiple categories can be specified, separated by commas. EnetCategories The Virtual Connect Ethernet trap categories to send to the destination. Valid values are "PortStatus", "PortThreshold", "Other", "All", and "None". FcCategories The Virtual Connect Fibre Channel trap categories to send to the destination. Valid values are "PortStatus", "Other", "All", and "None". Examples ->add snmp-trap EnetManagementStation Address=192.112.34.10 Community=private Format=SNMPv1 Severity=Normal,Critical EnetCategories=Other Adds a new trap destination for VC-Enet modules ->add snmp-trap FcManagementStation Address=192.112.72.3 Community=private Format=SNMPv1 FcCategories=Other Adds a new trap destination for VC-FC modules ->add snmp-trap MyTrap Address=192.112.66.12 Adds a new trap using typical defaults ->add snmp-trap MyTrap Address=192.112.42.5 Severity=All FcCategories=All DomainCategories=All Adds a trap with all severity and category properties set. Severities are allowed even though FC Categories are set; the severities will be applied to the Domain Item Description remove snmp-trap Removes a previously configured SNMP trap destination Syntax remove snmp-trap Parameter Name (required) The name of the trap destination to be removed. If "*" is specified, then all traps are Examples ->remove snmp-trap MyTrap1 Removes an SNMP trap destination
Community (optional) The SNMP community name string for the specified trap. The default value is
VC-FC modules, the maximum string length is 24.
Multiple severities can be provided, separated by commas. The default severity is
"None".
are "Legacy", "DomainStatus", "NetworkStatus", "FabricStatus", "ProfileStatus",
"ServerStatus", "EnetStatus", FcStatus", "All", and "None".
Multiple categories can be specified, separated by commas.
Multiple categories can be specified, separated by commas.
Categories.
removed.
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem