HP ProLiant DL180 Server User Manual
Page 45
Using LO100 45
—
Terminal Type—VT100
—
Sredir Memory Display Delay—No Delay
I/O Device Configuration—Configure IO Port
—
Serial Port 1 Address—3F8/IRQ4
o
On HP ProLiant ML115 G5, ProLiant DL165 G5, and ProLiant DL185 G5 servers, verify the
following settings:
Configure Console Redirection
—
Console Redirection—Enabled
—
EMS Support (SPCR)—Enabled
—
Flow Control—None
—
Redirection After BIOS POST—Always
—
Terminal Type—VT100
—
Sredir Memory Display Delay—No Delay
I/O Device Configuration-Configure IO Port
—
Serial Port 1 Address—3F8/IRQ4
o
On HP ProLiant DL120 G5 servers, verify the following settings:
Console Redirection
—
Console Redirection—Enabled
—
EMS support—Enabled
—
Baud Rate—115.2K
—
Terminal Type—VT100
—
Flow Control—None
—
Continue C.R. after POST—Enabled
I/O Device Configuration
—
Base I/O address—3F8
—
Interrupt—IRQ 4
o
On HP ProLiant ML150 G5 servers, verify the following settings:
Console Redirection
—
BIOS Serial console—Enabled
—
EMC Support (SPCR)—Enabled
—
Baud Rate—115.2K
—
Console Type—VT100
—
Continue C.R. after POST—On
I/O Device Configuration
—
Serial Port A—Enabled
—
Base I/O address—3F8
—
Interrupt—IRQ 4
o
On HP ProLiant DL160 G5 servers, verify the following settings:
- ProLiant DL180 G5 Server ProLiant ML150 G5 Server ProLiant ML110 G5 Server ProLiant DL160 G5p Server ProLiant DL120 G5 Server ProLiant ML115 G5 Server ProLiant DL165 G5 Server ProLiant DL160 G5 Server ProLiant DL165 G5p Server Lights-Out 100 Remote Management ProLiant SL165z G6 Server ProLiant DL185 G5 Server