Using the putty utility, Using the openssh utility, Using clp – HP ProLiant DL180 Server User Manual
Page 20: Using the putty utility using the openssh utility
Using LO100 20
NOTE:
Logging in to an SSH session could take up to 90 seconds. Depending on the client
used, you might not see on-screen activity during this time.
To access the remote management processor using SSH:
1.
Open an SSH window.
2.
When prompted, enter the IP address, login name, and password.
Using the PuTTY utility
PuTTY 0.54 is a terminal emulation product that includes support for telnet and the SSH protocol. PuTTY
0.54 is available for download from the Internet.
•
To start a PuTTY session, double-click the PuTTY icon in the directory in which PuTTY is installed.
•
To start a PuTTY session from the command line:
o
To start a connection to a server called host, enter:
putty.exe [-ssh | -telnet | -rlogin | -raw] [user@]host
o
For telnet sessions, you can also enter the following alternative syntax:
putty.exe telnet://host[:port]/
o
To start an existing saved session called session name, enter:
putty.exe -load "session name"
When you press Enter using PuTTY versions earlier than 0.54, two line feeds might appear on a single
line feed. To avoid this issue and for best results, HP recommends using version 0.54 or later.
Using the OpenSSH utility
OpenSSH is a free version of the SSH protocol available for download on the Internet.
To start an OpenSSH client in Linux, at the command prompt enter:
ssh -l loginname ipaddress/dns name
Using CLP
HP has worked with key industry partners within Distributed Management Task Force, Inc. to define an
industry-standard set of commands. The SMASH suite will standardize manageability interfaces for
servers. The Lights-Out 100 remote management processor implements the command set defined in the
Server Management Command Line Protocol Specification, 1.00 Draft. The CLP replaces the simple CLI
that was released previously and is no longer supported.
The management processor functionality accessible from the SMASH CLP is a low-bandwidth interface
and provides similar functionality to the web interface. The CLP is designed for users who prefer a
nongraphical interface. The CLP is accessible through the following methods:
•
Telnet
•
SSH connection
•
Physical serial port
- ProLiant DL180 G5 Server ProLiant ML150 G5 Server ProLiant ML110 G5 Server ProLiant DL160 G5p Server ProLiant DL120 G5 Server ProLiant ML115 G5 Server ProLiant DL165 G5 Server ProLiant DL160 G5 Server ProLiant DL165 G5p Server Lights-Out 100 Remote Management ProLiant SL165z G6 Server ProLiant DL185 G5 Server