HP ProLiant DL180 Server User Manual
Page 24
Using LO100 24
cd
version
exit
show
help
The first line of information returned by the show command is the current context. In the example, /.
is the current context. Following the context is a list of subtargets (Targets) and properties (Properties)
applicable to the current context. The verbs section (Verbs) shows which commands are available in
this context.
The show command can also be specified with an explicit or implicit context and a specific
property. An explicit context is /map1/firmware and is not dependent on the current context. An
implicit context assumes that the context specified is a child of the current context. If the current
context is /map1, then a show firmware command displays the /map1/firmware data. If a
property is not specified, then all properties are shown.
•
The load command moves a binary image from a URL to the map. The load command is used to
take a binary image from a specific source location (specified as a URL) and place it at the specified
target address. In a remote management processor implementation, the firmware downloads a full
image file using TFTP from the specified location and programs flash with the image.
In a remote management processor implementation, /map1/firmware is a valid target.
The load command supports usage only with the following options.
o
-source
o
(h)elp—This option appears on the command line. The command ignores all options and
properties except -output (for terse or verbose output). These options are only valid for this
command when the -help option is used.
o
source
value specified must be a valid URL. The format is //tftpserverip/path/filename. This
option is required in the command line when the load command is executed unless -help is
used. The file must be an uncompressed firmware image file that you create using the DOS
ROMPAQ utility found on the Lights-Out 100 Firmware Upgrade Diskette Utility available for
download from the HP website
To create the uncompressed image file, enter the following command from DOS:
ROMPAQ /D
where
uncompressed binary image file.
o
Specify one of the following:
—
"-oemhpfiletype csr" for loading firmware
—
"-oemhpfiletype key" for loading a key
—
"-oemhpfiletype cer" for loading a certificate
The load command returns any status data on the first lines. After the status data appears, one of
the following lines of text appears on the next line:
—
—
Example:
- ProLiant DL180 G5 Server ProLiant ML150 G5 Server ProLiant ML110 G5 Server ProLiant DL160 G5p Server ProLiant DL120 G5 Server ProLiant ML115 G5 Server ProLiant DL165 G5 Server ProLiant DL160 G5 Server ProLiant DL165 G5p Server Lights-Out 100 Remote Management ProLiant SL165z G6 Server ProLiant DL185 G5 Server