beautypg.com

Removing the library linkage – HP XP Command View Advanced Edition Software User Manual

Page 278

background image

2.

If this version is older than the prerequisite user SVC version of Smart Manager for Mainframe
after upgrading, disable (comment out) the

SYMDEF

statement that contains the

&YKSVCNO

system

symbolic name in the

IEASYMxx

parmlib member, as shown below:

/* SYMDEF(&YKSVCNO='SVC-number') */

3.

Disable (comment out) the

SVCPARM

statement that specifies the

JYUASVC

module of the

IEASVCxx

parmlib member, as shown below:

/* SVCPARM SVC-number,REPLACE,TYPE(3),EPNAME(JYUASVC),APF(NO),NPRMPT(NO),AR(NO) */

To apply the deletion of the user SVC, perform re-IPL by specifying the

CLPA

parameter. Perform re-IPL

at the end of the preparation for upgrading.

CAUTION:

A user SVC is shared by Smart Manager for Mainframe and Business Continuity Manager. Therefore,
in a system where Business Continuity Manager is installed, make sure that Business Continuity
Manager is not running before deleting the user SVC.

Related topics

Prerequisite user SVC versions for Smart Manager for Mainframe

, page 57

KTINSCHK

, page 173

Removing the library linkage

Remove all the links to libraries that were established during setup.

Procedure

1.

Remove the linkage of the

HPQYPRCT

cataloged procedure library.

• If the cataloged procedure library has been statically linked to the

IEFPDSI

DD name in the

MSTJCLxx

parmlib member, remove the linkage.

• If the

KTALCSVC

,

KTSETENV

, and

KTDSPENV

members have been copied from the cataloged

procedure library to the user's PROCLIB, delete those members.

2.

Remove the linkage of the

HPQYLNKT

load library for LINKLIB.

• If the load library for LINKLIB has been statically linked by adding it to the

PROGxx

parmlib

member, delete the load library from the member.

• If the load library for LINKLIB has been dynamically linked to

LNKLST

by using the

SETPROG

LNKLST

command, use the

SETPROG LNKLST

command to remove the linkage.

Upgrading Smart Manager for Mainframe

278