Setting logr couple data sets, Defining the sms for the system logger service, Defining a log stream – HP XP Command View Advanced Edition Software User Manual
Page 207: 207 defining the sms for the system logger service, 207 defining a log stream
Related topics
• Setting LOGR couple data sets
• Defining the SMS for the system logger service
• Setting access privileges for system logger resources
• Starting the system logger service
Setting LOGR couple data sets
In a sysplex environment, format the LOGR couple datasets and then define them for the sysplex.
Defining the SMS for the system logger service
To allocate staging datasets and log datasets used by the system logger service to an SMS management
volume, you must define the SMS for the Smart Manager for Mainframe system logger service.
You need to define the following items.
•
SMS storage group
•
Management class
•
Storage class
•
Data class
•
ACS routine
Defining a log stream
Use the IXCMIAPU utility to define a log stream.
Allocate one Smart Manager for Mainframe log stream to a system. In the sysplex environment,
allocate one log stream to each system in which Smart Manager for Mainframe is started.
Procedure
1.
Correct the parameters including the log stream name (
log_stream_name
) for the IXCMIAPU
utility shown below according to the environment.
The following is an example of parameters when an SMS definition is not used.
//DEFINE1 EXEC PGM=IXCMIAPU
//SYSPRINT DD SYSOUT=*
//SYSIN DD *
DATA TYPE(LOGR) REPORT(YES)
DEFINE LOGSTREAM NAME(log_stream_name)
DASDONLY(YES)
MAXBUFSIZE(64000)
STG_SIZE(800)
LS_SIZE(5000)
HLQ(CCENTRAL)
/*
2.
Execute the IXCMIAPU utility.
User Guide
207