P173 module status, P174 digital inputs, P175 digital outputs – NORD Drivesystems BU0270 User Manual

Page 58

background image

Supplementary Manual EtherCAT for NORDAC SK 200E

58

Subject to technical amendments

BU 0270 GB

Parameter

Setting value / Description / Note

Device

Supervisor

Parameter
set

P173 Module

status

0 ... FFFF (hex)

Possible values:
Bit 0 = Bus status "PRE-OPERATIONAL"
Bit 1 = Bus status "SAVE OPERATIONAL" or "OPERATIONAL"
Bit 2 = Timeout (EtherCAT)
Bit 3 = Timeout (time in P151)
Bit 4 = ASIC cannot be accessed
Bit 5 = General configuration error
Bit 6 = System bus “BUS WARNING”
Bit 7 = System bus "BUS OFF"
Bit 8 = Status FI 1
Bit 9 = Status FI 1
Bit 10= Status FI 2
Bit 11= Status FI 2
Bit 12= Status FI 3
Bit 13= Status FI 3
Bit 14= Status FI 4
Bit 15= Status FI 4

Status for FI x:

Bit High

Bit Low status

0

0

FI is offline

0

1

unknown FI

1

0

FI is online

1

1

FI missing or switched off

P174 Digital

inputs

0 ... 255

dec

(00000000 ... 11111111)

bin

Instantaneous view of input level logic.

Possible values:
Bit 0= Input 1 ((DIN1) (of BUS module))
Bit 1= Input 2 ((DIN2) (of BUS module))
Bit 2= Input 3 ((DIN3) (of BUS module))
Bit 3= Input 4 ((DIN4) (of BUS module))
Bit 4= Input 5 ((DIN5) (of BUS module))
Bit 5= Input 6 ((DIN6) (of BUS module))
Bit 6= Input 7 ((DIN7) (of BUS module))
Bit 7= Input 8 ((DIN8) (of BUS module))

P175 Digital

outputs

0 ... 3

dec

(00 ... 11)

bin

Instantaneous view of output level logic.

Possible values:
Bit 0= Output 1 ((DO1) (of BUS module))
Bit 1= Output 2 ((DO2) (of BUS module))