NORD Drivesystems BU0270 User Manual

Page 44

background image

Supplementary Manual EtherCAT for NORDAC SK 200E

44

Subject to technical amendments

BU 0270 GB

Index

Sub

Object

Description

Access

Type

0x1A00-
0x1A04*

0

Largest sub-index

Number of elements

RO

U8

0x1A00

0-1

TxPDO Mapping

Process data for the inputs of the SK TU4-ECT

RO

U32

0x1A01-

0x1A04

0-4

TxPDO Mapping

Actual values for FI 1 (0x1A01) to FI 4 (0x1A04)

RO

U32

0x1C00 0-4

Sync Manager

Com. Type

Shows the assignment and use of Sync channels

RO

U8

0x1C10 0

Sync Manager

Channel 0

Mailbox Receipt

RO

UCHAR

0x1C11 0

Sync Manager

Channel 1

Mailbox Send

RO

UCHAR

0x1C12 5

Sync Manager

Process Data Output

Process data output

RO

U16

0x1C13 5

Sync Manager

Process Data Input

Process Data Input

RO

U16

* xx00 hex = Bus module, xx01

hex

= FI 1, xx02

hex

= FI 2, xx03

hex

= FI 3, xx04

hex

= FUI 4,

5.3.2

Error codes – cancellation of parameter communication

The following table gives an overview of the possible error codes which may be generated on cancellation of
parameter communication.

Error code

Description

0x0503 0000

Toggle bit unchanged

0x0504 0000

Timeout of SDO message(Timeout of the SDO response by the bus module)

0x0504 0001

SDO command invalid / unknown

0x0504 0005

No memory (Insufficient memory)

0x0601 0000

Illegal access to an object

0x0601 0001

Reading access to write-only parameter

0x0601 0002

Writing access to read-only object

0x0602 0000

Object does not exist in the object dictionary (access to a non-existent parameter)

0x0604 0043

Parameter incompatibility

0x0604 0047

Module internally incompatible

0x0606 0000

Access failure due to hardware error

0x0607 0010

Data type or parameter length do not match

0x0607 0012

Data type incorrect, parameter length too long

0x0607 0013

Data type incorrect, parameter length too short

0x0609 0011

Sub-Index of parameter does not exist

0x0609 0030

Parameter value range overflow

0x0609 0031

Parameter value too large

0x0609 0032

Parameter value too small

0x0609 0036

Maximum value smaller than the minimum value

0x0800 0000

General error

0x0800 0020

Data transfer or saving not possible, as there is no communication between the bus module and the FI