NORD Drivesystems BU0270 User Manual
Page 51
6 Parameterisation
BU 0270 GB
Subject to technical amendments
51
Parameter
{Factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter
set
P514
CAN baud rate (system bus)
S
Setting of the transfer rate (transfer speed) via the system bus interface. All bus participants
must have the same baud rate setting.
0 =
10kBaud
1 =
20kBaud
2 =
50kBaud
3 =
100kBaud
4 =
125kBaud
5 =
250kBaud**
6 =
500kBaud
7 =
1Mbaud *
0 ... 7
{ 5 }**
*) Safe operation cannot be guaranteed
**) for communication with the bus module, the parameter must be left at the factory setting
(250kBaud) otherwise no communication is possible.
P515
...
[-01]
…
...
[-03]
CAN address (system bus)
S
Setting of the system bus address.
0 ... 255 dec
{ all 32 dec}
or { all 20 hex}
… [-01] =
Receive address for system bus
… [-02] =
Broadcast – Receive address for system bus (slave)
… [-03] =
Broadcast – Transmit address for system bus (master)
NOTE:
If up to four SK 200E are to be linked via the system bus, the addresses must be set as follows
FI 1 = 32, FI 2 = 34, FI 3 = 36, FI 4 = 38.
The system bus addresses should be set via the DIP switches 1/2 (Section 2.2.3).