Supplementary Manual EtherCAT for NORDAC SK 200E

18

Subject to technical amendments

BU 0270 GB

The double spring terminal bar is divided into 2 potential levels (system bus and digital outputs).
A separate power source should be used for the supply of the DOs. However, by bridging the 24V o and
GND o to one of the terminals of the system bus level (24V and GND) it is possible to implement the supply of
the DOs. However, in this case it should be noted that there is an increased risk of introducing interference into
the bus cables.
Connection of up to 8 sensors and 2 actuators is made via the terminal bar.

Digital inputs

System bus level and digital inputs

Digital outputs

24V

DIN 5

DIN 6

GND

24V

(as for 1)

24V

(as for 1)

24V

(as for 1)

GND

GND

DIN 1

GND

24V

(as for 1)

DIN 2

GND

24V

(as for 1)

24V

O

DO

DO 1

GND

O

DO

1

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

24V

(as for 1)

DIN 7

DIN 8

GND

24V

(as for 1)

24V

(as for 1)

Sys +

Sys -

GND

DIN 3

GND

24V

(as for 1)

DIN 4

GND

24V

(as for 1)

GND

O

DO

DO 2

GND

O

DO

Connection example: SK TU4-ECT to SK 200E

SK 205E... - bus connection unit (SK TI4)

SK TU4-ECT... - bus connection unit (SK TI4-TU-BUS)

Voltage
source
24V DC

NOTE

Looping of the 24V supply voltage is possible, however a maximum current load of 3A for

the SK TU4-ECT(-…) must not be exceeded.

Potential level: system bus

Potential level: system bus

Potential level: DOs