Performance, Reference conditions, Performance under reference conditions – West Control Solutions N6600 User Manual
Page 109: A-10

A.11
PERFORMANCE
Reference Conditions
Generally as EN60546-1.
Ambient Temperature:
20
°
C
±
2
°
C
Relative Humidity:
60 - 70%
Supply Voltage:
90 - 264V AC 50Hz
1%
Source Resistance:
<10
Ω
for thermocouple input
Lead Resistance:
<0.1
Ω
/lead balanced (Pt100)
Performance Under Reference Conditions
Common Mode Rejection:
>120dB at 50/60Hz giving negligible effect
at up to 264V 50/60Hz.
Series Mode Rejection:
>500% of span (at 50/60Hz) causes
negligible effect.
Thermocouple Inputs
Measurement Accuracy:
±
0.25% of span
±
1LSD.
Linearisation Accuracy:
Better than
±
0.2
°
C any point, any 0.1
°
C
range (
±
0.05
°
C typical). Better than
±
0.5
°
C
any point, any 1
°
C range.
Cold Junction
Compensation:
Better than
±
0.7
°
C.
RTD Inputs
Measurement Accuracy:
±
0.25% of span
±
1LSD
Linearisation Accuracy:
Better than
±
0.2
°
C any point, any 0.1
°
C
range (
±
0.05
°
C typical). Better than
±
0.5
°
C
any point, any 1
°
C range.
DC Output - Accuracy
Output 3 (Recorder
Output):
±
0.25% (mA @ 250
Ω
, V @ 2k
Ω
); Degrades
linearly to
±
0.5% for increasing burden (to
specification limits).
S075-A
A-10
PM-0075