7.30830.32.00

8

350

10

16x M20

75 (54.2)

400

10

16x M24

104 (75.2)

500

10

20x M24

107 (77.4)

600

10

20x M27

138 (99.8)

Meter
size
inches

Body
pressure
rating
psig

Bolts for
ANSI class
150 flanges

Max. torque
Nm (ft lbf)

8

145

8 x ¾”

69

(49.9)

10

145

12 x 7/8”

79

(57.1)

12

145

12 x 7/8”

104

(75.2)

14

145

12 x 1”

93

(76.2)

16

145

16 x 1”

91

(65.8)

18

145

16 x 1 1/8”

143

(103.4)

20

145

20 x 1 1/8”

127

(91.8)

24

145

20 x 1 ¼”

180

(130.1)

Note: Process pressure must not exceed ANSI flange rating. Refer to ANSI Standard B 16,5.

Other meter sizes on request.

1.4

Grounding IFS 4000 PF

The flowmeter (primary head) must be properly grounded.

The ground conductor must not transmit any interference voltages. Therefore, do not connect any other electrical devices

to this conductor.

Warning: Instrument must be properly grounded to avoid personnel shock hazard.

Metal pipeline, not internally coated

Electrically non-conductive pipeline

Grounding without grounding rings

Grounding with grounding rings (option)

RF

F

F

PE

RF

pipeline

pipeline

V2

V1

E

Grounding rings, option, see sect. 1.2.

F

Flowmeter flanges

PE

Protective earth, wire

4 mm

2

(10

AWG) Cu, not included with supply, to
be provided by customer. IFS 4000 PF
connected to U-clamp terminal on
“neck” of primary head.

PE

E

E

F

F

RF

V1

V2

pipeline

RF

pipeline

RF

Pipe

V1, V2

Connecting wires, bolted to the “neck” of
the IFS 4000 PF. Threaded holes to be
provided for M6 bolts for flange-side (RF)
connection.
Use factory-supplied mounting material for
connection of grounding rings E.