KROHNE TIDALFLUX IFM 4110 PF EN User Manual
Page 33
7.30830.32.00
33
Setting of totalizer format
•
Auto (exponent notation)
•
# . # # # # # # #
•
# # # # # . # # #
•
# # . # # # # # #
•
# # # # # # . # #
•
# # # . # # # # #
•
# # # # # # # . #
•
# # # # . # # # #
•
# # # # # # # #
Select with
↑ and ↓ keys.
Press
↵ key to change to subfunction “DISP. MSG.”.
→
→ DISP. MSG. = additional messages desired in measuring mode , press → key
•
NO
no additional messages
•
YES
display additional messages, e.g. errors, in sequence with measured values)
Select with
↑ and ↓ keys.
Press
↵ key to change to subfunction “DISP.LEVEL”.
→
→ DISP.LEVEL = measured relative level desired in measuring mode , press → key
•
NO
no display
•
YES
display measured relative height, in sequence with measured values
Select with
↑ and ↓ keys.
Press
↵ key to return to Fct. 1.04 DISPLAY
Note: “BUSY” is displayed in measuring mode when all displays are set to “NO DISP.” or “NO”.
Sequencing of displays is automatic. In measuring mode, however, keys
↑
and
↓
can be used for manual sequencing. Return
to automatic sequencing after approx. 3 minutes.
Please refer to Section 2.5.7 “Standard factory settings”
5.5
Internal electronic counter
The internal electronic totalizer counts in m
3
regardless of the unit set in Fct. 1.04, subfunction “DISP. FLOW”.
The counting range depends on the meter size and has been selected such that the totalizer will count for at least 1 year
without overflow.
Meter size
Counting range
DN mm
inch
in m
3
US Gal equivalent
200
8
0 – 9 999 999.9999999
0 – 2 641 720 523.5800
250 – 600
10 – 24
0 – 99 999 999.9999999
0 – 26 417 2050235.800
Only a part of the totalizer count is shown in the display as it is not possible to display a 14-digit number. Unit and format of
the display are freely selectable. Refer to Fct. 1.04, subfunction “DISP.TOTAL.” and sect. 5.4 to determine which part of
the count is to be displayed. Display overflow and totalizer overflow are independent of one another.
Example
Internal count
0000123.7654321 m
3
Format, display unit
XXXX.XXXX
liter
Internal count in unit
0123765.4321000 liter
Displayed
3765.4321