7.30830.32.00

68

Part D

Technical Data, Measuring Principle and Block Diagram

10.

Technical data

10.1

Primary head IFS 4000 PF

10.1.1 General information

Meter sizes and versions
Meter sizes

DN200 – 1600 / 8” – 64”

Connecting flanges

DIN2501

DN200 – 600 / PN 10

ANSI B16.5

8” – 24” / 150 lb

AWWA and others

on request

Protection category

IP 67, equivalent to NEMA 6 (IEC 529 / EN 60529)

Hazardous-duty version

optionally Ex N, Zone 2

Process data
Liquid product

water and waste water

Electrical conductivity

≥ 50 µ

S/cm

Flow level in pipe

min. 10 % of inside tube diameter

Process temperature

- 5 to + 60°C / + 23 to + 140F

Ambient temperature

- 25 to + 60°C / - 13 to + 140F

Operating pressure

max. 10 bar / 150 psig

Integrated flow measuring system
Measuring principle

electromagnetic flow measurement

Full-scale range

in pipe running full between 34 m

3

/h or 160 US Gal / min (minimum for DN200 / 8”)

and 100 000 m

3

/h or 500 000 US Gal / min (maximum for DN1600 / 64”)

equivalent flow velocity 0.3 – 12 m/s or 1 – 40 ft/s

Electrode design

1 pair of electrodes, solidly fitted, surface polished

Power for field coils

from signal converter

Grounding rings

available as an option

Integrated level measuring system
Measuring princple

capacitive level measurement, built into the measuring tube liner

Pipe filling

min. 10% of inside tube diameter, outputs go to “zero” below 10% filling

Power

Voltage, frequency

230 / 115 V AC, 50 – 60 Hz, others on request

Power consumption

14 VA

Communication with converter

via RS485 interface

Electronics housing

compact, mounted on primary head

Cable entries

3 x PG 16 and 1 x PG 9, optionally ½” NPT or ½” PF

Materials of construction
Measuring tube

stainless steel 1.4301 (or higher material numbers) / AISI 304

Liner

Irathane

®

, 12 mm / 0.47”

Electrodes

Hastelloy C4, others on request

Connecting flanges

*

steel 1.0038 (RST 37.2)

Converter housing

*

sheet steel

Electronics housing

*

cast aluminium

PG cable entries

nickel-plated brass

Grounding rings (option)

stainless steel 1.4571 / AISI 316 Ti