beautypg.com

KROHNE TIDALFLUX IFM 4110 PF EN User Manual

Page 38

background image

7.30830.32.00

38

•• Characteristic of status outputs

Switch open

Switch closed

OFF (switched off)

no function

ON (e.g. operation indicator)

power supply OFF

power supply ON

SIGN I (F/R mode)

forward flow

reverse flow

SIGN P/P2 (F/R mode)

forward flow

reverse flow

FULL SCALE (full-scale indicator)

inactive

active

AUTO. RNG. (automatic range
change)

high range

low range

OVERFL. I (I range exceeded)

current output O.K.

current output range exceeded

OVERFL. P/P2 (P range exceeded)

pulse output O.K.

pulse output range exceeded

ALL ERRORS

error

no error

FATAL. ERRORS

error

no error

INVERS A1: Status output A2…

when A1 is closed

when A1 is open

INVERS D1: Status output D2…

when D1 is closed

when D1 is open

EMPTY PIPE (empty tube
identification option)

when measuring tube is empty

when measuring tube is full

For factory settings please refer to sect. 2.5.7.

5.10

Control inputs C1 and C2

Fct. 1.11 CONTROL C1

and/or

Fct. 1.12 CONTROL C2

Press

→ key

Press

→ key

Select function for the control inputs, press

↑ or ↓ key

OFF

switched off, no function

OUTP. HOLD

hold output values

Function also acts on display and totalizer

OUTP. ZERO

set outputs to “min. values”

Function also acts on display and totalizer

TOTAL. RESET

reset totalizer

ERROR. RESET

acknowledge/delete error messages

EXT. RNG.

external range change for automatic range change, see sect. 5.20.
Settling range 5 – 80 PERCENT = low to high ratio 1:20 to 1:25, value must be greater than
that of Fct. 1.03 L.F. CUTOFF.

Press

→ key to change to numerical setting, 1st number (cursor) flashes.

Change flashing number (cursor) with keys

↑ and ↓. Use ← and → keys to shift cursor 1 place to left or right.

Flashing numbers can also be directly set with the 10-key keyboard.

Press

↵ key to return to Fct. 1.11 CONTROL C1 or to Fct. 1.12 CONTROL C2.

Please refer to sect. 2.5.7 for factory settings.

Connection diagram see sect. 2.5.6.

5.11

Language

Fct. 3.01 LANGUAGE
Press

→ key

Select language for texts in display

D

German

GB/USA

English

F

French