64

8.4

Replacing single printed circuit boards (PCBs)

Switch off the power supply before opening the housing.

1) Remove the cover from the terminal compartment (remove 2 screws).
2) Pull all cables out of the plug-in terminals.
3) Remove the glass cover from the control compartment (remove 4 screws).
4) Remove 4 screws from the front panel, take hold of the handle on the upper end of the front panel and carefully pull out

the complete electronic unit of the signal converter housing.

5) Put down the electronic unit with the front panel F facing down.
6) Remove screw(s) S

LP

from the PCB(s) to be replaced and carefully pull out the PCB(s) of the plug base(s). Fit new

PCB(s), refer to the illustration in sect. 8.3.

When replacing the PCBs FSV and/or ADC, always remove both PCBs together as they have a common plug-
and-socket connector.

When replacing the ADC PCB, carefully move the data EEPROM IC14 from the old to the new PCB and
observe the direction of the IC during plugging. After changing the EEPROM from the old to the new electronic unit,
no further adjustments or settings are required. Refer to the illustration in sect. 8.5.

7) Re-assemble in reverse order (items 6 – 1 above)

8.5

Illustrations of printed circuit boards (PCBs)

Power unit PCB, NT, 100 – 230 V AC

X1

plug-in terminals inside terminal compartment

X2

internal connection to motherboard

T

transformer

Small fuses TR5, values and Order No. see sect. 9:
F1

5 V voltage

F2

field current supply

F3

current output and power supply

F4

auxiliary voltage

F7

power supply

F8-F10 coupling elements

Inputs/outputs PCB, I/O