Limits, Operation, Setting limits – Lincoln Electric IM946 CRUISER Digital Tractor User Manual
Page 97

Cruiser™ Tractor
OPERATION
10-20
10-20
Set Limits:
Press for 5 Seconds
Memory 2
Set Limits
Limits
Limits allow the welder to adjust the welding procedure only within a defined range.
Each memory may have a different set of limits. For example, memory 1 may limit the
WFS to 100 through 120 in/min; memory 2 may limit the WFS to 140 through 160
in/min; and memory 3 may have no WFS limits.
Parameters are constrained by machine limits or by setting memory limits. When
memory limits are enabled, the parameter will flash whenever an attempt is made to
exceed the memory limit value. The parameter will not flash if an attempt is made to
exceed the machine limit.
Note:
Weld modes cannot be selected through the Limits Setup menu and must be
chosen and saved to memory before entering the Limits Setup Menu.
Setting Limits
1. Press the desired memory button 1
through 4 and hold for 5 seconds.
Release the memory button when the
LED begins to blink rapidly and the
MSP4 displays “Memory X Set Lim-
its.”
2. If the passcode does not equal zero
(0000), enter the passcode. If the
passcode is unavailable or forgotten,
a p.c. computer application or Palm
O.S. application is required to
change the passcode.