beautypg.com

Setup features menu, Exit user prefs – Lincoln Electric IM946 CRUISER Digital Tractor User Manual

Page 101

background image

Cruiser™ Tractor

OPERATION

10-24

10-24

Setup Features Menu

The Setup Menu provides access for configuring user preferences, which are generally only set at installation. The
user preferences are grouped as shown in the following table.

ACCESSING THE SETUP MENU

1. ACCESS

To access the Setup Menu, Press the Left Button and
Right Button simultaneously. The Setup Menu Indicator
will light and the lower display will read as shown below.

Note: The Setup Menu cannot be accessed during weld-
ing, or if a fault is displayed. To resume welding, exit the
Setup Menu.

2. PREFERENCE SELECTION

Scroll through the Preference list by rotating the Control
Knob. Press the Right Button to edit the selected prefer-
ence.

3. PREFERENCE CHANGE

Scroll through the preference options by rotating the
Control Knob. Change the preference setting by press-
ing the Right Button. To cancel, press the Left Button.

4. EXIT

To exit the Setup Menu, press both buttons simultane-
ously or select P.0 and press the Left Button. Sixty sec-
onds of inactivity will automatically exit the Setup Menu.

Note: If a product is missing any of the preference op-
tions listed below, a software update may be needed
from www.powerwavesoftware.com.

FIGURE B.7 - SETUP MENU

P

.

0

Exit

User Prefs

Setup Menu

Indicator

Mode Select

Panel (MSP)

Left Button

Control Knob

Right Button

PARAMETER

P.1 through P.99

P.101 through P.199
P.501
through P.599

DEFINITION

Unsecured Parameters (always adjustable)

Diagnostic Parameters (always read only)

Secured Parameters (only accessible with Weld Manager)