Operation – Lincoln Electric IM946 CRUISER Digital Tractor User Manual
Page 105

Cruiser™ Tractor
OPERATION
10-28
10-28
Parameter
Definition
P.501
Encoder Lockout
Locks one or both of the upper knobs (encoders), preventing the operator from changing wire feed
speed, amps, volts or trim. The function of each upper knob depends on the selected weld mode.
When a constant current weld mode is selected (e.g. Stick, TIG, Gouge), the upper right knob will
always function as an on/off switch. This parameter can only be accessed using PowerWave Man-
ager software.
P.502
Memory Change Lockout
Determines if the memories can be overwritten with new contents.
No = Memories can be saved and limits can be configured (default).
Yes = Memories cannot be changed - saving is prohibited and limits cannot be re-configured.
This parameter can only be accessed using Power Wave Manager software.
P.503
Memory Button Disable
Disables the specified memory button(s). When a memory is disabled, welding procedures can-
not be restored from or saved to that memory. If an attempt is made to save or restore a disabled
memory, a message will be displayed on the lower display indicating the memory number is dis-
abled. In multi-head systems, this parameter disables the same memory buttons on both feed
heads. This parameter can only be accessed using Power Wave Manager software.
P.504
Mode Select Panel Lock
Selects between several Mode Select Panel lockout preferences. When a Mode Select Panel se-
lection is locked and an attempt is made to change that parameter, a message will be displayed
on the lower display indicating the parameter is locked. All MSP Options
Unlocked = All adjustable parameters on the Mode Select Panel are unlocked. All MSP Options
Locked = All knobs and buttons on the Mode Select Panel are locked.
Start & End Options Locked = The Start and End parameters on the Mode Select Panel are
locked, all others are unlocked.
Weld Mode Option Locked = The weld mode cannot be changed from the Mode Select Panel,
all others Mode Select Panel settings are unlocked.
Wave Control Options Locked = The Wave Control parameters on the Mode Select Panel are
locked, all others are unlocked.
Start, End, Wave Options Locked = The Start, End and Wave Control parameters on the Mode
Select Panel are locked, all others are unlocked.
Start, End, Mode Options Locked = The Start, End and Weld Mode Select parameters on the
Mode Select Panel are locked, all others are unlocked.
This parameter can only be accessed using Power Wave Manager software.
P.505
Setup Menu Lock
Determines if the setup parameters can be modified by the operator without entering a passcode.
No = The operator can change any set menu parameter without first entering the passcode even
if the passcode is non-zero (default).
Yes = The operator must enter the passcode (if the passcode is non-zero) in order to change any
setup menu parameters.
This parameter can only be accessed using Power Wave Manager software.
USER DEFINED PARAMETERS (CONT.)