beautypg.com

Operation, Constant current – Lincoln Electric IM946 CRUISER Digital Tractor User Manual

Page 84

background image

Cruiser™ Tractor

OPERATION

10-7

10-7

Current Held

Constant

and

Wire Feed

Speed Varied

and

Constant Arc Length

Maintained

AMPS

Extension

Heating = VIR Total Electrical

Stickout

V = Vir + Varc

Arc Length = Varc

Wire Feed Speed

Constant Current

Operator presets current and desired voltage.

The power source:

- Maintains a constant arc length

- Drives a constant current

- Synergetically controls WFS to maintain voltage at the desired set point.

Arc length is proportional to voltage.

Constant current is traditionally used for larger diameter wires and slower travel

speeds.

Figure 10-3 Constant Current