beautypg.com

Percent dc offset, Operation – Lincoln Electric IM946 CRUISER Digital Tractor User Manual

Page 90

background image

Cruiser™ Tractor

OPERATION

10-13

10-13

500

-500

0

-1000

1000

Nominal Offset

Positive Offset

More Penetration

Less Deposition

Negative Offset

Less Penetration

More Deposition

Percent

DC Offset

5. Set the DC offset (sine wave or

square wave weld modes only).

DC Offset (Variable Amplitude) - Control Penetration

Wave amplitude and the duration of positive and

negative cycles are independently adjustable, so the

operator can obtain deep/shallow penetration and

higher/lower deposition rates depending

on the application.

Increasing

negative
amplitude

(offset)

decreases

penetration

Increasing

positive

amplitude

(offset)

increases

penetration