beautypg.com

IAI America E-Con User Manual

Page 68

background image


54

Position Data Table (Columns with the thick lines indicate the input insert)

No.

Position

Speed

Acc/Dec

Push

Positioning Band

Acc. only Max

0 *

*

*

*

*

*

1 150 200 0.3

0

1

0

2 200 100 0.3

0

0.1

0

:

























T1: Over 6 msec

Time from Command Position Select Input to Start Signal ON


(However, please consider the scan time of the upper controller.)


Caution:

Positioning complete Output will turn OFF and moving output will turn on once the start signal turns
ON. Please execute Start Signal OFF only after confirming that moving output turns ON with Start
Signal ON status.