2-6 Wiring

2-6-1 Wiring for Power • Emergency Stop
























*

The two EMG terminals are emergency-stop switch contact terminals of the contact-b input logic. They have
been shorted at the factory so that an emergency stop will not be actuated.

24 VDC is output to pin 1.

Caution: When wiring power at the customer site, please make sure that the following specifications are met.



Applicable conduit

Single Line -

1.0 (AWG18)

Stranded Line - 0.75 mm

3

(AWG18)

Specification possible conduit

range

Single Line -

0.4 (AWG26) to 1.2 (AWG16)

Stranded Line - 0.3 mm

2

(AWG22) to 1.25 mm

2

(AWG16)

Stranded Diameter - Over

0.18

Length of un-sealed connect wire 11 mm

Applicable tool for button

operation

Minus Driver (axis diameter

3, blade point width 2.6)

Caution: This controller does not have a power switch.