Programming the com ports, continued, Device attached, Enter – Fairbanks FB6002 INSTRUMENTATION User Manual
Page 53: Settings, Baud rate, parity, stop bits, data bits, format, Checksum
![background image](/manuals/347095/53/background.png)
Section 6: Serial Input / Output
01/13
53
51293 Rev. 2
6.2. PROGRAMMING THE COM PORTS, CONTINUED
4. When
DEVICE ATTACHED
DEVICE ATTACHED
DEVICE ATTACHED
DEVICE ATTACHED
displays, press
ENTER
.
5. Using the down arrows, select the correct device (noted below), then press
ENTER
.
•
PC Continuous – Displays weight
continuously.
•
TM-U295
•
SP-700
•
PC Polled – Displays weight when
button is pressed.
•
IDP-3550
•
SP-298
•
Off – Does not display weight.
•
TM-U230
•
SP-2000
•
Remote Display
•
TM-U590
•
SP-22000
•
DemandPC – The external device sends out a polling request (i.e. CR,
“W”, etc.), and the instrument responds with return data. GTN format.
6. When
SETTINGS
SETTINGS
SETTINGS
SETTINGS
displays, press
ENTER
.
7. Enter the appropriate Port Parameter Settings of the
BAUD RATE, PARITY,
STOP BITS, DATA BITS, FORMAT
and
CHECKSUM
, according to the
specifications in Section 9.4. Printer Switch Settings.