beautypg.com

Menu system, Relay menu – GF Signet 9900-1BC Batch Controller System User Manual

Page 19

background image

19

9900-1BC Batch Controller Manual

R1 Normal Open/Closed

Set Open Collector (R1) as Normally Open or Normally Closed.

Default = NORMAL OPEN.

Relay Mode

Select the desired mode of operation for the open-collector (R1) output.

Simple Mode: BATCH, VOL PULS, MISSING.

Advanced Mode: OFF, BATCH, HI FLOW, VOL PULS, EOB PULS, MISSING, OVERRUN,

SRC VOL (if SOURCE VOL is set to ON; see OPTIONS menu), TOT VOL, TWO STG, MULTIPLE, ERROR.

Defaults: Relay 1 = VOL PULS; Relay 2= BATCH; Relay 3 = MISSING.

Note:

Same Relay Modes are available for Relays 2 and 3. See pg. 10-12.

Test Relay

Select OFF or ON to test relay.

View Remote Button Status

Press ► to view status of remote buttons.

Remote Button Status

Displays status of Remote Buttons: STA (Start), STP (Stop), RES (Resume).

1 = pressed, 0 = not pressed. Press ENTER to exit.

RELAY Menu

Set Flow

In HI FLOW Mode, set fl ow value to activate relay.

Set Hysteresis

Prevents the system from chattering around the set point.

In HI FLOW Mode, Relay is energized at Set Flow value and will be de-energized

at Set Flow value minus Hysteresis value.

Set On Delay

In HI FLOW, ERROR, and MISSING Modes, set desired ON delay. Default = 5 sec.

Stop Batch?

In HI FLOW, MISSING, MULTIPLE, and ERROR Modes,

determines if a Batch is stopped when a Relay Activates. If YES is selected,

Batch will be stopped; if NO is selected, Batch will continue. Default = YES.

Set Overrun Volume

In OVERRUN and MULTIPLE Modes, set desired

Overrun Volume.
Note:

Overrun Volume must be greater than Manual Overrun Compensation, otherwise the Overrun Alarm

will activate at the end of every batch.

Set Totalizer Volume

In TOT VOL Mode, set desired totalizer volume.

Note:

This volume is resettable and totalizer volume must be reset to clear relay.

(see Resettable Totalizer, pg. 16)

Set Pulse Volume

In VOL PULS Mode, set desired volume.

Set Pulse Width

In VOL PULS Mode, set desired pulse width.

Menu System