GF Signet 2551 Magmeter Flow Sensor - Blind User Manual

Signet 2551 blind magmeter, English, Quick start guide

background image

1

2

3

4

JP2

FREQUENCY OUT
SERIAL (S

L) OUT

3

Connect output signals and power
to this 4-terminal block.

1.

Sensor Type

Pipe Size

Jumper Position

2551-P0/T0/V0

½ in. to 2½ in.

DN15

to

DN65

2551-P0/T0/V0

3 in. to 4 in.

DN80

to

DN100

2551-P1/T1/V1

5 in. to 6 in.

DN125

to

DN150

2551-P1/T1/V1

8

in.

DN200

2551-P2/T2/V2

10 in. to 12 in.

DN250

to

DN300

2.

3.

4.

5.

4.

Signet 2551 Blind Magmeter

*3-2551.090*

3-2551.090

Rev L 10/12 English

1. Quick Start Guide

This manual contains the general installation, wiring and calibration data for the Signet 2551-XX-11 Magmeter with Frequency or
Digital (S

3

L) data output, and for the Signet 2551-XX-12 Magmeter with 4 to 20 mA output. The basic steps are outlined on this page.

See each referenced section for detailed information.

1. Con¿ gure the Hardware

2551-XX-11 ONLY: Position this Jumper to select

Digital (S

3

L) output or Frequency output. Sec. 5 Pg. 4.

2.

Position the PIPE SIZE jumper according to your

pipe size. Sec. 5 Pg. 4.

3.

Install the Magmeter into the pipe.

Use Signet installation ¿ ttings ONLY.
The installation ¿ tting is critical to Magmeter

performance. Sec. 3 Pg. 3.

4.

Connect POWER and OUTPUT wiring.

Frequency out: Sec. 8.1 Pg. 6.
Digital

(S

3

L) out: Sec. 8.2 Pg. 6.

4 to 20 mA out: Sec. 7 Pg. 5.

GROUNDING

Without a good earth ground, the Magmeter may not

operate ef¿ ciently. Sec. 6 Pg. 5.

5.

Route the wiring out through the two cable ports.

Use appropriate hardware to secure the 2551 from
moisture intrusion. One Liquid Tight Connector is
included. Sec. 5 Pg. 4.

Topic:

Page

1.

Quick

Start

Guide

1

2.

Speci¿

cations

2

3. Installation: Pipe Fittings

3

4.

Selecting

a

Location

3

5.

Hardware

Con¿

guration

4

6. General Installation and Grounding Tips

5

7. Wiring the Magmeter with 4 to 20 mA Loop

5

Topic:

Page

8. Wiring the Magmeter

with Frequency or Digital (S

3

L) Output

6

9. Calibration and Software Con¿ guration

6

10.

Calibration

Data

7

11. Maintenance and Troubleshooting

11

12.

Ordering

Information

12

English

Description

The Signet 2551 Magmeter is an insertion-style magnetic À ow sensor. The patented sensor design is available in a variety of corrosion-
resistant materials to provide long-term reliability and minimal maintenance costs. Wetted material combinations include PP/316 SS,
PVDF/Hastelloy-C and PVDF/Titanium. The 2551 installs quickly and securely into a wide selection of À ow ¿ ttings to deliver accurate
À ow measurement in pipe sizes ranging from DN15 to DN900 (½ in. to 36 in.).

Signet 2551 Magmeters are available with a frequency output or Digital (S

3

L) output for use with the Signet 5600 Batch Controller, 8900

Multi-Parameter Controller or 9900 Transmitter, or with a 4 to 20 mA output for a direct input to a PLC, SCADA or telemetry system.

All 2551 Magmeters feature empty pipe detection and LED-assisted diagnostics. The Signet 3-0250 USB to Digital (S

3

L) set-up tool is

available to customize every performance feature in the 2551 to adapt it to the speci¿ c application requirements.