beautypg.com

GF Signet 525 Metalex Flow Sensor User Manual

Signet 525 metalex flow sensor, English

background image

3. Sensor/Fitting

Selection

The 525 is designed for installation into SCH 40 stainless steel pipes
via the Signet Metalex Tee, Mini-Tap or Saddle fi ttings, see options
below:

Signet Metalex Tee Fittings (Sensor PN P525-1/-1S)
Pipe (in.)

Fitting

Code

0.50

P526-2005

198 840 501

0.75

P526-2007

198 840 502

1.00

P526-2010

198 840 503

Signet Metalex Mini-Tap Fittings (Sensor PN P525-2/-2S)
Pipe (in.)

Fitting

Code

1.25

P526-2012

159 000 494

1.50

P526-2015

198 840 506

2.00

P526-2020

159 000 495

2.50

P526-2025

159 000 496

3.00

P526-2030

159 000 497

4.00

P526-2040

159 000 498

5.00

P526-2050

159 000 499

6.00

P526-2060

159 000 500

8.00

P526-2080

159 000 501

10.0

P526-2100

159 000 502

12.0

P526-2120

159 000 503

Maximum Operating Temperature/Pressure:

Signet 525 Metalex Sensor with:

• Signet 526-1XXX Series Saddle Fitting:

21 bar @ 66 °C (300 psi @ 150 °F)

• Signet 526-2XXX Series Tee and Mini-Tap Fitting:

103 bar @ 149 °C (1500 psi @ 300 °F)

Signet 525 Metalex Flow Sensor

1. Location of Fitting

Recommended sensor upstream/downstream
mounting requirements.

45°

45°

2. Sensor Mounting Position

• Horizontal pipe runs: Mount sensor in the upright (0°) position for

best overall performance. Mount at a maximum of 45° when air
bubbles are present. Do not mount on the bottom of pipe when
sediments are present.

• Vertical pipe runs: Sensor must be mounted in lines with UPWARD

fl ow only.

Tee Fitting,

hardware included

+GF+

525-1

Sensor

(525-1S for stainless steel)

Wetted fitting materials:
316 SS

+GF+

Mini-Tap Fitting,

hardware included

525-2

Sensor

(525-2S for stainless steel pin)

Wetted fitting materials:
316 SS & 347 SS

SAFETY INSTRUCTIONS
1. Do not remove from pressurized lines.
2. Do not exceed maximum temperature/pressure specifi cations.
3. Pipe fi tting must be installed by certifi ed welder only.
4. Do not install/service without following installation instructions

(see sensor manual).

5. Wear safety goggles and face shield during installation/service.
6. Do not alter product construction.
7. Failure to follow safety instructions could result in severe

personal injury!

*P52590-1*

P52590-1 Rev.

P

10/12

English

English

15x I.D.

5x I.D.

20x I.D.

5x I.D.

40x I.D.

5x I.D.

25x I.D.

5x I.D.

50x I.D.

5x I.D.

Reducer

90° Elbow

2 x 90° Elbow

3 dimensions

2 x 90° Elbow

Pump/Valve