beautypg.com

GF Signet 3719 pH_ORP Wet-Tap User Manual

Signet 3719 ph/orp wet-tap, English

background image

Signet 3719 pH/ORP Wet-Tap

Do not exceed maximum temperature/pressure specifi cations.

Wear safety goggles or face shield during installation/service.

Do not attempt to disassemble the retraction housing and the
electrode piston.

Do not alter product construction.

Failure to follow safety instructions may result in severe
personal injury.

Retract electrode before any pipe cleaning operation.

1. Description

The Signet 3719 pH/ORP Wet-Tap allows installation and removal of pH or ORP electrodes without the need for process shutdown
during routine electrode maintenance and calibration. Process isolation is achieved with a double O-ring seal on a unique and
compact retraction assembly; no separate valve is required. A cam-activated automatic locking mechanism, SafeLoc™, and the short
stroke design help to assure operator safety.

1. Description
2. Specifi cations
3. Dimensions
4. 3719 System Overview
5. Installation
6. Maintenance & Cleaning
7. Troubleshooting
8. Ordering Information

*3-3719.090*

3-3719.090

Rev L 12/11

English

English

General
• Compatible

sensors:

2716-WT Twist-Lock pH Electrode

2717-WT Twist-Lock ORP Electrode

2756-WT

DryLoc

®

pH Electrode

2756-WT-1

DryLoc

®

pH Electrode

2756 -WTP DryLoc

®

plastic pH electrode

2756-WTP-1

DryLoc

®

plastic pH electrode

2757-WT

DryLoc

®

ORP Electrode

2757-WTP

DryLoc

®

plastic ORP electrode

• Shipping

Weight:

Wet-tap assembly:

1.2 kg (2.7 lbs.)

Electrode:

0.13 kg (0.3 lb)

Process Connection:

3-3719-11: 1½ in. NPT

3-3719-21: 2 in. NPT

3-3719-12: ISO 7/1-R1½

3-3719-22: ISO 7/1-R2

2. Specifi cations

Storage Temperature:

Wet-tap assembly:

-15 to 120 °C (5 to 248 °F)

Electrode:

0 to 50 °C (32 to 122 °F)

Wetted materials
• Retraction

Housing: CPVC

• O-rings:

FPM

Electrode Body:

Glass OR Plastic

Electrode junctions:

Porous PTFE

Electrode sensing surface:

Glass Membrane (pH)

Platinum

(ORP)

• Electrode

O-rings:

FPM

WARNING!
If used in conditions that exceed recommended
pressure ratings, this product can pose a serious
hazard.
We urge customers to read the specifi cations
carefully before installing and operating this product.
Improper use can cause components and process
liquids to be expelled at high speeds and cause
serious personal injury.

Other Materials
• Locking

Shroud:

PVC

Hardware:

316 stainless steel

Performance

Maximum Flow Velocity: 3 m/s (10 ft/s)

• Effi ciency:

> 97% @ 25 °C (77 °F)

Response Time:

pH: <5s for 95% of signal change

ORP:

Application

dependent

Drift:

< 2 mV per week

Operating Range:

pH: 0 to 14 pH

ORP: –2000 to +2000 mV

Reference Junctions:

Porous PTFE

• Electrolyte:

3.5M

KCl

• Elements:

Ag/AgCl

Temp. Sensor (pH):

3K Balco (3-2716-WT,

3-2756-WT-1, WTP-1)

PT1000 (3-2756-WT, -WTP)

Temp. response time (

 438 s

Sodium Ion Error:

< 0.05 pH in 0.1 molar

Na+ ion at 12.8 pH

Impedance (pH):

<150 MΩ @ 25 °C

Standards and Approvals

Manufactured under ISO 9001 and 14001

25

China RoHS (Go to www.gfsignet.com for details)