Maintenance, cleaning
Installing swivel plate
→
Connect swivel plate to the spindle.
→
Align bores of the swivel plate and spindle.
→
Support swivel plate on the cylindrical part with the aid of a
prism or something similar.
→
Insert pin into the bore.
→
Swage pin bores on both sides of the swivel plate using a chisel
or center punch.
Spindle
Pin
Swivel plate
Fig. 27: Swivel plate
Installing the actuator on the valve body
For description see chapter entitled “Installing the actuator on the
valve body”, page 26
12.
MALFUNCTIONS
Malfunction
Remedial action
Actuator does
not switch.
Pilot air port interchanged
8)
CFA:
Connecting pilot air port 1
CFB:
Connecting pilot air port 1
CFI
Pilot air port 1: Open
Pilot air port 2: Close
Pilot pressure too low
See pressure specifications on the type label.
Medium pressure too high
See pressure specifications on the type label.
Flow direction reversed
See direction arrow on the body.
english
Type 2100
- Type 0125 (15 pages)
- Type 0121 (4 pages)
- Type 0330 (2 pages)
- Type 0331 (4 pages)
- Type 6012 (4 pages)
- Type 0127 (18 pages)
- Type 0131 (5 pages)
- Type 0141 (5 pages)
- Type 0142 (12 pages)
- Type 0145 (3 pages)
- Type 0174 (5 pages)
- Type 0212 (2 pages)
- Type 0211 (5 pages)
- Type 0212-B (18 pages)
- Type 0250 (64 pages)
- Type 0253 (2 pages)
- Type 0255 (15 pages)
- Type 0355 (2 pages)
- Type 0255 (2 pages)
- Type 8006 (34 pages)
- Type 8640 (2 pages)
- Type 8640 (55 pages)
- Type 8640 (119 pages)
- Type 0256 (15 pages)
- Type 0256 (2 pages)
- Type 0258 (72 pages)
- Type 0262 (5 pages)
- Type 0273 (6 pages)
- Type 0280 (5 pages)
- Type 0280 (2 pages)
- Type 0280 (12 pages)
- Type 0281 (2 pages)
- Type 0282 (2 pages)
- Type 0283 (2 pages)
- Type 0286 (4 pages)
- Type 0287 (15 pages)
- Type 0290 (2 pages)
- Type 0290 (14 pages)
- Type 0293 (18 pages)
- Type 0300 (6 pages)
- Type 0301 (6 pages)
- Type 0311 (2 pages)
- Type 0312 (6 pages)
- Type 6518 (57 pages)
- Type 6519 (3 pages)