beautypg.com

Burkert Type 2100 User Manual

Page 14

background image

14

Technical data

Medium and pilot pressure for control function A, flow direction
below the seat (standard)

Orifice
DN

Maximum medium pressure

[bar]

Minimum pilot pressure

[bar]

Actuator size ø [mm]

Actuator size ø [mm]

50

70

90

130

50

70

90

130

15

25

25

-

-

5,2

4,8

-

-

20

16

20

25

9

16

32

-

8,5

16

-

5

40

6

16

50

-

10

16

5

65

5

16

-

5,6

Tab. 3: Medium and pilot pressure for CFA, standard

Medium and pilot pressure for control function A, flow direction
below the seat reduced pressure spring force (EC04)

Orifice
DN

Maximum medium pressure

[bar]

Minimum pilot pressure

[bar]

Actuator size ø [mm]

Actuator size ø [mm]

50

70

90

130

50

70

90

130

15

14

16

-

-

3,2

2,5

-

-

20

6

12

25

3

6

32

-

3,5

9

-

2,5

40

2

6

16

2,5

50

-

3,5

11

-

65

-

7,5

-

3,2

Tab. 4: Medium and pilot pressure for CFA, reduced pressure

spring force (EC04)

english