Technical data, Conformity 7.2. standards, Type label – Burkert Type 2100 User Manual
Page 12: Conformity, Standards
12
Technical data
7.
TECHNICAL DATA
7.1.
Conformity
Type 2100 conforms with the EC Directives according to the EC
Declaration of Conformity.
7.2.
Standards
The applied standards, which verify conformity with the EC Direc-
tives, can be found on the EC-Type Examination Certificate and / or
the EC Declaration of Conformity.
7.3.
Type label
Example:
00175102
2100 A 25M PTFE VA
Tmed -10°C - +180°C
Flow 1 2
Pilot 4,8-10bar
Pmed 16,0bar
G1" Kv20
W3ZLT
CE
Fig. 5: Example of the type label
WARNING!
Risk of injury from high pressure!
Important device-specific technical specifications are indicated on
the type label.
• Observe permitted pressure range on the type label of the
device.
Example:
00175102
2100 A 25M PTFE VA
Tmed -10°C - +180°C
Flow 1 2
Pilot 4,8-10bar
Pmed 16,0bar
G1" Kv20
W3ZLT
CE
CE identification
Permitted
pilot pressure
Permitted
medium pressure
Type
Control function
(CF)
Orifice of the body /
actuator size
Sealing material
1)
Body material
1)
ID number of
the device
Flow direction
Permitted medium
temperature
Date of manu-
facture (encoded)
Main dimensions
port connection
Flow capacity in
standard production
conditions
1)
For description of versions see “7.5. General technical data”
english
Type 2100